New downloads available from ProvideX Comments (<Error>)   providexodbc
Wed, Apr 14, 2004 18:40:09  

    Today was a busy day for Best. They issued two new downloads on their site. The new ProvideX ODBC Manual, and an update to v6 for Windows and WindX only that corrects a couple of major issues (version 6.00.0009) (Don't worry that when you try to download the file and it says it was dated back in March, it really is the new download on the site).

    I haven't reviewed the new ODBC manual yet, but it has been described as

This brand new document covers the following topics in detail:

  • Installation & Activation Procedures
  • Local & Client Configuration
  • Server Configuration (Windows and UNIX/Linux)
  • Table Definitions (Data Dictionary & INI file)
  • SQL Syntax Table With Example SQL Statements

    The changes to ProvideX are in the new readme file (still named pvx600.txt) and are the following items

    1.152 - Corrected an issue where PRINT 'PICTURE'() to a *WINPRT* device, did not always output the picture. The issue is very dependant on the Printer Drivers in use, and the revision of the GDI layer in Windows. Not every OS or installation will suffer from this issue due to a mix of dependancies.

    2.5 - Correction for ERR=41 occuring, when doing file I/O across a WindX connection, with V6 WindX.

    2.6 - Allowed for a longer (45 second) delay, rather than a short (5 second) delay for incoming data, when in the middle of a packet transmission. Previously this would show as a CRC error, rather than a timing error. A high-latency or congested network, could see spurious CRC Errors on WindX clients.

    2.7 - Corrected an issue where WindX in Telnet mode, may not complete its connection to a server, when setting the Terminal Type, and the telnet server daemon asked 2 or more telnet questions requiring responses at the same time, when those questions happened to arrive together, and the terminal type question was not the first question.

    11.5 - Corrections to the ASCII Character mode interface

    11.6 - Modifications to the Buffer Management within the App Server Daemon to allow for faster buffer draining to the outlying workstations, as well it now avoids giving "preferential" treatment to any given instance of ProvideX on any one workstation.

    11.7 - Corrections in WindX for using SSL connections to a UNIX/Linux App Server.

    11.8 - Corrected a problem where the Allow Client to Set Start-In Directory was not being saved when configuring an Application.

    11.9 - Corrections to App Server / WindX where a V6 WindX would not display log-in screens.

 
Latest Headlines
SDSI's New Website
Thank you to Steve Litwak for Donating
VIM syntax file for ProvideX
Toronto Business Basic Meetup next week (Feb 9, 2005)
The Announcement to MAS90 MDs
Top Examples
PCL5 Commands - Lists an extensive range of PCL5 command codes
Example of using ProgCtrl from the MS Control Library
Simple Report 1 - Integrate Crystal Reports into your app!
Retrieve information from LDAP/Active Directory by Username
Examples of using new ProvideX 5.10 features

New FAQ
What's with the PayPal icon?
Can I use ProvideX to screen scrape a webpage?
Who is Nth Dimension and how can I get in touch with you?

RSS Badge
 
PayPal Donate Link Visit PVXHost to get your own ProvideX powered website Get Firefox! 
Copyright © 1998-2005, Nth Dimension